(Troubleshooting codes cont.)
coDe
PossIBLe cause
10
Low water supply.
11
Leak at high-pressure hose fitting.
12
Nozzle obstructed.
13
Water filter screen clogged.
14
Air in hose.
15
Choke lever in the CHOKE position.
16
High-pressure hose is too long.
17
Spray wand not in low pressure.
18
Chemical filter clogged.
19
Chemical screen not in cleaning solution.
20
Chemical too thick.
21
Worn seal or packing.
22
Chemical build up in chemical injector.
23
Worn or obstructed valves.
24
Worn unloader piston.
25
Worn or broken o-ring.
PossIBLe soLutIon
Water supply must be at least 5 GPM @ 20 PSI (138 kPa).
Repair leak. Apply sealant tape if necessary.
See nozzle cleaning under Maintenance.
Remove and clean filter.
Turn off the engine, then the water source. Disconnect the
water source from the pump inlet and turn the water source
on to remove all air from the hose. When there is a steady
stream of water present, turn water source off. Recon nect
water source to pump inlet and turn on wa ter source. Squeeze
trigger to re move re main ing air.
Move choke to the NO CHOKE po si tion.
Use high-pressure hose under 100 feet (30.48 m). Lengthen water
supply hose instead of high-pressure hose.
See spray Wand nozzles under Operation.
Clean filter.
Make sure end of chemical hose is fully submerged into cleaning
solution.
Dilute chemical. Chemical should be the same consistency as water.
Have parts cleaned or replaced by authorized service center.
Have replaced by an authorized service center.
Have replaced by authorized service center.
Have replaced by authorized service center.
Check and replace.