A. Control Panel
NOTE: Total power drawn from all receptacles must not exceed
the nameplate ratings.
B.
120 V, 20 Ampere Receptacle
20 amps of current may be drawn from the receptacle,
provided it is not limited by the circuit protector size. Total
power drawn must be kept within nameplate ratings.
C. 120/240 V, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from the
120/240 volt receptacle, provided it is the only receptacle
used. Total current must be limited to the nameplate
rating. If the 120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.
D. Receptacle Covers
E.
Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before attempting to use the
generator again. If overloading causes the circuit protector to trip,
reduce the load. NOTE: Continuous tripping of the circuit
protector may cause damage to generator or equipment. The
circuit protector may be reset by pushing the button of the protector.
F.
Ground Terminal
G. Engine On/Off/Start Switch
H. Tank Clamping Knob
I.
420 CC OHV Engine
J.
Recoil Starter
O
R
F
G
K
N
J
English
GENERATOR FEATURES
GENERATOR FEATURES
K. Engine Choke Lever
L.
M. Oil Drain Plug
N. Air Filter
O. Fuel Tank
1, right hand Acme threads (not supplied with generator).
P.
Q. Fuel Regulator (under shroud)
R. Multimeter
P
Q
B
E
C
A
D
12
Oil Filler Cap
Standard 20 or 30 pound capacity DOT LP Gas tank with Type
Fuel Shut-Off Valve
Valve is on the fuel tank (not supplied with generator).
• When the generator is started, the voltage value is shown first.
• Press and release the mode button to toggle between Voltage,
Frequency, Total Hour Meter and Run/Maintenance
Timer.
• Voltage (V) displays the operating voltage of the generator.
• Frequency (F) displays the frequency in hertz at which the
generator is running.
• The Run/Maintenance Timer displays the time in hours and
minutes each time the generator is ran. The run timer resets
to 00:00 when the generator is shut off. Built into this run
timer is a maintenance reminder. When the new generator is
ran for 25 hours, the meter will display P25. This is to
remind you to change the oil after the initial 25 hours of run
time.
• When the Run/Maintenance Timer displays P50, it is
reminding you to clean the air filter and change the oil.
• When the Run/Maintenance Timer displays P100, it is
reminding you to change the fuel filter, clean the air filter, and
change the oil.
L
M
I
Customer Hotline 1-800-445-1805
H