Descargar Imprimir esta página

Louisiana Grills LG700 Montaje Y Operación página 25

Publicidad

Idiomas disponibles

Idiomas disponibles

The Digital Control Center system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
LG – ELECTRIC REQUIREMENTS
110V, 3.3AMP, 60HZ, 375W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety
testing and certification services, comply with a testing
tolerance of ± 5-10 percent.
GRILL PROBE SPADE
CONNECTORS
S
N
S
N
GRILL PROBE
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
300W, 120V, 2.6AMP,
9.5MM x 127MM (0.375" x 5.000")
INDEX
W : WHITE
K : BLACK
Y : YELLOW
N : BROWN
B : BLUE
S : SILVER
R : RED
G : GREEN
ELECTRICAL WIRE DIAGRAM
TEMPERATURE
SETTING SWITCH
°F
°C
DIGITAL CONTROL CENTER
°F
K
R
B
Y
W
°C
CONNECTOR BOX (8 PIN)
K
R
B
Y
W
W
R
W
W
Y
AUGER FEED SYSTEM
115V, 50/60HZ,
30W, 0.5AMP,
2 RPM MOTOR
HOPPER ACCESS PANEL
LOCATE AND REMOVE THE
EIGHT SCREWS ON SIDE
OF HOPPER TO ACCESS
ELECTRICAL COMPONENTS
FAST-BLOW FUSE
5 AMP
WIRE HARNESS
CONNECTOR BOX
W
W W
W
W
W
K
B
W
W
W
B
W
B
GROUNDED
POWER CORD
VW-1, 105°C/221°F,
18-3 STANDARD CSA
GROUND
G
COMBUSTION & COOLING FAN
115V, 50/60HZ, 0.21/0.19AMP,
CFM110, 1 PHASE
25

Publicidad

loading

Este manual también es adecuado para:

Lg serie60700