6 Choose a suitable position for the adjuster.
NOTE:
● The staple might not drive deep enough if using high
pressure with the adjuster set upwards (shallow side)
due to factors such as the material hardness or staple
type.
If that happens, reduce pressure and set the adjuster
to lowest position so the staple drives in at a good
position.
USING THE BLOW NOZZLE
● Be sure to release your fi nger from the trigger
before using the blow nozzle.
● Do not point the air outlet of blow nozzle at a
person.
● Do not use the blow nozzle when depress the
push lever against the workpiece.
This Stapler has a blow nozzle that blows out wood
shavings which occur during work.
Press the knob with your thumb to use the blow nozzle, as
shown in the fi gure.
Blow nozzle knob
Air outlet of
blow nozzle
NOTE
● When the blow nozzle is used for a long time, the
Stapling force may degrade temporarily. In this case,
allows the air supply pressure to stabilize before
starting work.
● Oil in the body or drained water from the compressor
can sometimes spout out of the air outlet of blow
nozzle. It is recommended that you once conduct a
test before use and see if such phenomenon happens
at an environment where spouted oil will cause any
inconvenience.
18
WARNING
CHANGING THE EXHAUST DIRECTION
● When changing the exhaust direction, be
sure to remove your fi nger from the trigger
and disconnect the air hose from the stapler.
The direction of the exhaust vent can be changed by
turning the top cover.
Exhaust vent
USING THE NOSE CAP
● When detaching or attaching the nose cap,
be sure to remove your fi nger from the trigger
and disconnect the air hose from the stapler.
The nose cap is attached to the push lever tip to protect
the workpiece from scratches or damage. Remove in the
order shown below when not using.
1 DISCONNECT AIR HOSE FROM STAPLER.
2 Pull out the nose cap in the direction of the arrow as
shown in the diagram.
○ Attach to the tip of the push lever in the reverse order
of detaching.
Firing head
Push lever
Nose cap
WARNING
Top cover
WARNING
Disconnect air
1