MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 3 – 7).
● Disconnect air hose and remove all staples
from Stapler when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed staple in the following order:
1 DISCONNECT AIR HOSE.
2 Remove all staples.
3 Release the lock lever and open guide plate.
3
Lock lever
3
Guide plate
4 Remove the jammed staple with a slotted-head
screwdriver.
Guide plate
5 Close guide plate and latch.
6 In case of frequent jam, contact a metabo HPT
authorized service center.
2. Storing
○ When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
20
MAINTENANCE
WARNING
1
Disconnect
air hose
○ Do not store the Stapler in a cold weather
environment.
Keep the Stapler in a warm area.
○ When not in use, the Stapler should be stored in a
warm and dry place.
Keep out of reach of children.
3. WARNING LABEL
Do not use the Stapler with missing or damaged
WARNING LABEL.
A new WARNING LABEL is available from a
metabo HPT authorized service center.
4. Maintenance chart (See page 21)
5. Operator troubleshooting (See page 21)
CAUTION
● In the operation and maintenance of power tools,
the safety regulations and standards prescribed
in each country must be observed.
SERVICE AND REPAIRS
● Only
service
metabo HPT, distributor or employer
shall repair the Stapler.
● Use only parts supplied or recommended by
metabo HPT for repair.
All quality Staplers will eventually require servicing or
replacement of parts because of wear from normal use.
NOTE:
Specifi cations are subject to change without any
obligation on the part of metabo HPT.
Warning label
WARNING
personnel
trained
by