MAINTENANCE AND INSPECTION
WARNING
● Be sure to switch power OFF and disconnect the plug from the receptacle during maintenance and
inspection.
● Using cracked, deformed or damaged wheels can lead to wheel breakage and resulting serious injury.
1. Replacing the depressed center wheel
Replace the depressed center wheel when it has been
worn out to about 2-3/8" (60mm) in external diameter.
Confi rm that there is no crack or any damage to
the depressed center wheel. If there is a crack or a
transformation in the wheel, replace it immediately.
2. Inspecting the screws
Regularly inspect all screws and ensure that they are
fully tightened. Should any of the screws be loosened,
retighten them immediately.
WARNING
Using this grinder with loosened screws is
extremely dangerous.
3. Confi rm that there is no damage in the wheel guard,
the electrical cord and the housing, etc.
Check that the on/off switch operates normally.
4. Replacing supply cord
If the supply cord of Tool is damaged, the Tool must
be returned to metabo HPT Authorized Service
Center for the cord to be replaced.
5. Service and repairs
All quality power tools will eventually require servicing
or replacement of parts because of wear from normal
use. To assure that only authorized replacement parts
will be used, all service and repairs must be performed
by a metabo HPT AUTHORIZED SERVICE CENTER,
ONLY.
6. Filter cleaning and inspection
WARNING
Wear protective glasses and a dust mask when
cleaning the fi lter with an air blow gun.
Failure to do so may result in inhalation or
exposure of the eyes to debris or dust.
After use, remove any debris or dust adhered to
the fi lter using a soft brush. (Fig. 7) Check the fi lter
periodically to ensure that it is free of scratching,
chipping, or tearing. Replace with a new fi lter if the
fi lter is damaged in any way.
NOTE
If the mesh is clogged and the debris or dust cannot
be removed, detach the fi lter and clean it with an air
gun, etc. (See "Exchanging the fi lter set (Fig. 8)")
Filter
Mesh
7. Filter set replacement
Removal procedure (Fig. 8)
(1) Use a fl athead screwdriver to unclip the two clips
joining the bottom and side fi lters.
(2) Push out the bottom fi lter in the direction indicated by
the arrow.
(3) Removing the bottom fi lter also allows the removal of
the two side fi lters.
Unclip
Flathead
screwdriver
Bottom fi lter
Side fi lter
English
Soft brush
Fig. 7
Unclip
Push out
Side fi lter
Fig. 8