Descargar Imprimir esta página

Stanley FATMAX HY 227/8/6E Manual De Instrucciones página 20

Ocultar thumbs Ver también para FATMAX HY 227/8/6E:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
3.
Open gently the drain valve.
4.
Keep the compressor tilted until all moisture has been removed.
G
5.
Close the drain valve.
B
Warning!
The
condensation
water
contain residual oil. Dispose of the condensation water in an
environmentally compatible manner at the appropriate collection
point.
7.3 Safety valve (ref. G)
The safety valve has been set for the highest permitted pressure of the
pressure vessel. It is prohibited to adjust the safety valve or remove its
seal. Actuate the safety valve from time to time to ensure that it works
when required. Pull the ring with sufficient force (fig. 7) until you can
hear the compressed air being released. Then release the ring again.
7.4 Checking the oil level
The compressor is life lubricated. In any case, periodically check the
oil level.
Place the compressor on a level and straight surface. Remove the oil
dipstick (Fig. 8) and wipe the dipstick. Re-insert the dipstick into the
filler opening as far as it will go. Pull out the dipstick and read off the
oil level. The oil level must be between the two marks MAX and MIN
on the oil dipstick (Fig. 8).
Warning!
The possible topping up of oil should be done with extreme caution.
Should it be necessary to top up, at the end of the operation, the oil level
should NOT exceed the mark MAX on the oil dipstick.
Use SAE 40 mineral oil. Never mix different grade oils.
9. TROUBLESHOOTING GUIDE
Note: Remove power source and drain tank pressure prior to making any repairs or adjustments.
FAULT
Leakage of air from the valve of the
pressure switch with the compressor off.
Reduction of performance. Frequent start-
up. Low pressure values.
The compressor stops and restarts
automatically after a few minutes.
After a few attempts to restart, the
compressor stops.
The compressor does not stop and the
safety valve is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine
may impair its safety and in any case make the warranty null and void.
Warranty and repair.
In the event of defective goods or requirements for spare parts, kindly contact the sales point where you made your purchase.
from
the
pressure
vessel
Check valve that, due to wear or dirt on the
seal, does not perform its function correctly.
Excessive performance request, check for
any leaks from the couplings and/or pipes.
Intake filter may be clogged.
Tripping of the thermal cutout due to
overheating of the motor.
Tripping of the thermal cutout due to
overheating of the motor (removal of the
plug with the compressor running, low
power voltage).
Irregular functioning of the compressor or
breakage of the pressure switch.
7.5 Storage
Warning!
Pull the mains plug out of the socket and ventilate the appliance
and all connected pneumatic tools.
will
Switch off the compressor and make sure that it is secured in
such a way that it cannot be started up again by any unauthorized
person.
Warning!
Store the compressor only in a dry location which is not
accessible to unauthorized persons.
Always store upright, never tilted!
8. DISPOSAL AND RECYCLING
The unit and its accessories are made of various types of material,
such as metal and plastic.
Defective components must be disposed of as special waste. Ask your
dealer or your local council.
CAUSE
Unscrew the hexagonal head of the check
valve, clean the valve seat and the special
rubber disk (replace if worn). Reassemble
and tighten carefully.
Replace the seals of the fitting, clean or
replace the filter.
Clean the air ducts in the conveyor.
Ventilate the work area.
Activate the on/off switch. Ventilate the work
area. Wait a few minutes. The compressor
will restart independently.
Remove the plug and contact the Service
Center.
20
REMEDY

Publicidad

loading