13. MAINTENANCE AND CARE
A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
finished charging. Wipe off any battery
fluid that may have come in contact with
the clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the
finish shiny and help prevent corrosion.
14. TROUBLESHOOTING
PROBLEM
Charger will not turn
on when properly
connected.
No reading on the
ammeter.
Ammeter reading
stays high.
Ammeter reads less
than selected charge
rate when charging a
discharged battery.
POSSIBLE CAUSE
AC outlet is dead.
Poor electrical connection.
Charger is not plugged in.
No power at the receptacle.
Clamps are not making a good
connection to the battery.
Connections are reversed.
Battery is defective
(will not accept a charge).
Battery is severely discharged.
Wrong battery voltage.
Extension cord is too long or
wire gauge is too small.
Weak cell or sulfated plate in
battery.
Battery is only partially
discharged.
• Coil the input and output cords neatly
when storing the charger. This will help
prevent accidental damage to the cords
and charger.
• Store the charger unplugged from the AC
power outlet in an upright position.
• Store inside, in a cool, dry place. Do not
store the clamps clipped together, on or
around metal, or clipped to the cables.
Check for open fuse or circuit
breaker supplying AC outlet.
Check power cord and extension
cord for loose fitting plug.
Plug the charger into an AC outlet.
Check for open fuse or circuit
breaker supplying AC outlet.
Check for poor connection to battery
and frame. Make sure connection
points are clean. Rock clamps back
and forth for a better connection.
Unplug the charger and reverse
the clamps.
Have the battery checked.
Continue charging battery for two
more hours. If problem continues,
have the battery checked.
Check battery voltage.
Use a shorter or heavier gauge
extension cord.
A sulfated battery will eventually
take a normal charge if left
connected. If the battery will not
take a charge, have it checked.
Continue to charge the battery.
• 10 •
REASON/SOLUTION