12. Troubleshooting guide
Case 1. Starting failure
WARNING
Make sure the icing prevention system is not
working.
Check fuel for water
or substandard mix-
ture.
Check for engine
flooding.
Check the spark.
Case 2. Lack of power/Poor acceleration/ Rough
idling
Check fuel for water
or substandard mix-
ture.
Check air filter and
fuel filter for clogging.
Check carburetor
for inadequate ad-
justment.
Case 3. Oil does not come out
Check oil for sub-
standard quality.
Check oil passage
and ports for clog-
ging.
If the unit seems to need further service, please
consult with an authorized service shop in your area.
Replace with proper
fuel.
Remove and dry the
spark plug.
Then pull the starter
again with no choke.
Replace with a new
plug.
Replace with proper
fuel.
Clean.
Readjust speed needles.
Replace.
Clean.