Descargar Imprimir esta página

Dometic RTX2000 Instrucciones De Instalación página 12

Ocultar thumbs Ver también para RTX2000:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Installation
z The downward slope of the roof in forward direction in the area where
the unit is installed must not be more than:
– RTX1000: 8°
– RTX2000: 20°
z The assembly parts supplied must not be modified during installation.
z The ventilation openings must not be covered over (minimum distance
from other external attachments: 100 mm).
z Follow the vehicle manufacturer's guidelines when installing the
system and establishing the electrical connections.
I
NOTE
After installation of the system, the pre-set parameters on the system
software must be checked (chapter "Configuring the system software"
on page 14).
6.2
Removing the roof hatch
Proceed as follows (fig. 5):
➤ Remove all screws and fixings for the existing roof hatch.
➤ Take out the roof hatch.
➤ Remove the sealant around the opening so that the surface is clean
and free of grease.
I
NOTE
Dispose of all waste material, glue, silicon and seals separately. When
doing so, follow the waste disposal requirements applicable in your local
area.
6.3
Preparing the unit fixings
(Iveco Stralis Hi-Way only)
➤ Drill out the 12 factory-made holes to a diameter of 8.5 mm (fig. 6).
10
CoolAir RTX1000, RTX2000
EN

Publicidad

loading

Este manual también es adecuado para:

Rtx1000