Sensor Clip
2
1
Sensor
Battery Clip
Battery Clip
Installation
Installed
Replace the Sensor
CAUTION: Risk of product damage. Do not disconnect the
connectors by pulling on the wires.
Carefully disconnect the wires by pulling gently on the
connectors.
Pull the loop outward to disengage the clip from the groove.
Rotate the clip counterclockwise.
Remove the old sensor.
Attach the new sensor wires to the connectors.
Install the sensor in the faucet, wire side first.
Align the sensor eyes with the holes in the spout.
Place the straight end of the clip into the hole in the retaining
wall of the spout.
Pull the clip out until the bend in the clip is resting at the
entrance to the groove. Avoid pinching the wires between the
sensor and clip.
Push the clip in until it is firmly seated in the groove.
Kohler Co.
Connector
Position 1
9
Connector
Position 2
1025498-5-H