SEQUENCER menu
Here you will set up different rhythmic patterns for each channel. As there are 6 channels (or slots), there
are 6 patterns completely independent of each other. However, they all share the same TEMPO in BPM.
Magerit METRO has two types of sequencers: a step sequencer and a Euclidean sequencer. We will see
how each one works. To switch between the two types of sequencers, press and hold the
more than 3 seconds. The "SEQ->STEP" or "SEQ->EUCLID" will flash on the display. To save the changes
(sequencer type, tempo, parameters...), press and hold the
otherwise the sequencer type will be changed and nothing will be saved.
Press briefly
to pause or play the sequence. If there is an external clock signal, the button will have no
effect. The external clock plays the sequences following the tempo (rythm) set by the input signal, coming
from any other Eurorack module. If this signal is paused, METRO will detect it.
STEP SEQUENCER
Grids of adjustable length and selectable steps. On each channel you can select a different sequence
length, pattern or ratio.
Turn the encoder to scroll horizonta-
lly. Press and hold while turning the
encoder to move vertically.
Press the encoder to turn on or off
the specific step (where the cursor
is).
1 - Number of steps of the selected
sequence.
2 - TEMPO (in BPM). If an external
clock signal is connected, this po-
tentiometer will have no effect.
Current channel
playback position
2/17
BPM: 120
Cursor - Encoder
position
1
2
button, but no longer than 3 seconds,
The number indicates the chan-
nel of the sequence. If the pause
symbol appears, it means that the
sequence is paused.
If there is a play icon at the bottom
of the display, an external clock sig-
nal is connected. The pause symbol
÷2
indicates that the whole sequencer
is stopped.
3 - Ratio of the selected channel. In
1/16 external clock mode, there will
be multiples of up to x4.
3
4
4.- ON/OFF, activate or deactivate
the sequence
18
button for