Starting
A reference run must be carried out for the first
starting and after exchange of one of the drives. In
this process the drive will determine its zero point
(Closed-position). This single event is called null
balance.
- Connect drive
- Trigger drive in CLOSED-direction
(independent on the position of louvres)
After an overload cutoff has been effected in
running direction „CLOSED", the drive will have a
new zero point. During the reference run, no
obstacle must impair the running of the louvres.
The hand guard in arms's reach is
deactivated during the reference
run (danger of squeezing)!
Maintenance and cleaning
Maintenance work is only allowed when the device is in
a de-energized condition! Inspection and maintenance
has to be carried out according to D+H maintenance
notes. Only original D+H spare parts may be used.
Repair is to be carried out exclusively by D+H.
Wipe away debris or contamination with a dry, soft
cloth. Do not use cleaning agents or solvents.
Stroke limiting with magnets (not ACB)
1
Close drive.
Special magnet
MAG 502
99.828.02 1.3/01/20
Troubleshooting
Wiring:
Is the drive or drive group wired properly?
See connection plans.
Diagnostics with SCS software (only ACB):
The SCS software and a BSY+ interface (BI-BT 2
or BI-USB) is required for further troubleshooting or
configuration.
Disposal
Electrical devices, accessories, batteries and packa-
ging should be sorted for environmental-friendly
recycling. Do not dispose electrical devices and
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for
waste electrical and electronic equipment and its
implementation into national right, electrcal devices
that are no longer usable must be collected separa-
tely and disposed of in an environmentally correct
manner.
2
Voltage must continue to
be applied to the drive when
moving in the "CLOSE"
direction. Hold the magnet next
to the drive as shown in the
diagramme (2 sec.) until you hear
a pulsating ton > The drive is now
in learning mode. The magnet can
now be removed and the drive no
longer has to be under voltage.
appr. 2 sec.
learning mode
English
LDx-5
3
Allow the drive to run
"OPEN" until you reach the
required stroke.
If the stroke is set incorrectly,
the procedure is accidentally
interrupted or the drive
continues to the full stroke
length, please return to point 1
and start again.
STOP
LDx 1x00-5 /-ACB
7/20