6) Thread mounting nut onto fill valve shank and tighten the nut.
N OTE: Do not over-tighten. Be sure to install fill valve in a position that does not
interfere with the trip lever operation.
7) Connect water supply to fill valve shank and hand-tighten only.
NO TE: Do not overtighten. These are plastic parts. Never use pipe dope on any
water supply connection.
8) Attach refill tube to fill valve nipple and clip other end of refill tube to the overflow
pipe.
9) Turn water supply ON and check for leaks outside the tank.
NO TE: As water fills the tank, water is also directed into the overflow tube via the
refill tube. This additional flow of water is critical to refilling your toilet's bowl.
Once the water stops filling the tank, some residual drops of water may drip
from the fill valve. This is NORMAL as these drops will subside.
Depending on the manufacturing plant, you may have one of two of the following fill
valves:
For Type A Fill Valve:
Refer to the water level (WL) setting
marked on the inner wall of the tank. Allow
the water to fill the tank. Turn the adjust-
ment screw clockwise in the (+) direction to
increase the water level height (see Illustra-
tion 1). Turn the adjustment screw counter-
clockwise in the (-) direction to decrease
the water level height. Flush the toilet to
verify the correct water level. Adjust as
necessary.
For Type B Fill Valve:
There are no water level adjustments. The
fill valve has been preset at the factory.
WARNING!
DO NOT USE IN-TANK BOWLCLEANERS. The use of high concentration of chlorine
or chlorine-related products can seriously damage fittings in the tank. This damage
can cause leakage and property damage. TOTO
for any tank fitting failure or damage caused by the use of in-tank bowl cleaners.
Replacement Procedure (continued)
Water Level Adjustment
Type A
CARE AND CLEANING
Type B
WATER
LEVEL
Ill. 1
shall not be responsible or liable
®
7
Top of
Overflow
WL
Tube