wood, cardboard, nails, etc.) represents a
safety hazard and consequently must not be
left within the reach of children. Keep it all
for further transportation or long layup
periods (see paragraph 4.2). Before
connecting the appliance, check that the data
on the rating plate correspond to those of the
available power supply mains. The ironer
must only ever be used for the purpose it was
strictly designed for.
5. INFORMATION REGARDING THE
INSTALLATION OF THE APPLIANCE
5.1. POSITIONING REQUIREMENTS
Apart from a flat floor, these ironers do not
need any particular requirement as far as
positioning is concerned. The rear wall of the
appliance may be placed against a wall, as the
appliance is a front-service type.
For fume-extracting versions, sufficient
space must be granted for a chimney to
discharge the fumes produced during
ironing (see fig. 1)
Level the appliance by the adjustable feet
and by resting a water level on its side
panels. Check that the weight is distributed
uniformly on the feet, and that the machine
does not shake. If the appliance is to be
shifted to another position, carry out the
levelling procedure again.
5.2. INSTALLATION, USE AND MAIN-
TENANCE OF THE IRONER (see fig.1)
Leave some space on both sides of the ap-
pliance in order to allow access during main-
tenance or repair jobs, as shown in fig.1:
1) Front face of appliance;
2) Ironing roller;
3) Control board;
4) Automatic cutout switch (not supplied)*;
5) Side panel containing extracting system;
6) Available equipotential connection;
7) Electric power supply cable inlet with
cable protecting duct;
8) Steam expelling pipe;
* The automatic cutout switch must be
placed so that it can be easily actuated by
the operator in any EMERGENCY event
(maximum distance 3 m).
5.3. ROOM CONDITIONS REQUIRED
FOR CORRECT OPERATION OF THE
APPLIANCE (information for the user)
- TYPE OF PREMISES: CLOSED
- MINIMUM TEMPERATURE: 10
- MAXIMUM TEMPERATURE: 40
- RELATIVE HUMIDITY : 75% R.H.
- ILLUMINATION: 100 LUX (applicable
in Italy; considering the differences among
the different national standards, reference
must be made to the local norms effective in
your country).
5.4. ELECTRICAL CONNECTION
(see fig.2)
The appliance must be installed by qualified
personnel following the manufacturer's
All manuals and user guides at all-guides.com
instructions and in compliance with the local
standards for electric installations in force in
the relevant country. The manufacturer de-
clines all responsibility for injury to people
or animals or damage to property arising
from incorrect installation.
Unscrew and remove the right side panel
fastened by four cross-slotted screws. Check
that power supply voltage corresponds to the
rating plate values. Power voltage variations
must not exceed ±10% of the nominal value.
IMPORTANT:
IT IS COMPULSORY TO CONNECT
THE APPLIANCE TO THE EARTH
SYSTEM. For this purpose the machine
features an appropriate earth terminal.
This connection must absolutely comply
with the regulations in force. The
manufacturer declines all responsibility
concerning regardlessness of this safety
rule.
In accordance with the latest safety standards,
the appliance features also an external
terminal for equipotential connection.
It is necessary to install an automatic multi-
polar cutout switch on the electric supply
line ahead of the machine. Contacts must
space no less than 3 mm. The cutout switch
msut be adjusted according to the maximum
electric absorption (see data on the rating
plate and in the table below):
MODEL N° of
poles
100/25
4
120/25
4
140/25
4
140/25AV 4
CAUTION
Machines featuring an inverter provide a
current leak to earth of 5-8 mA, which is
owed to the installation of the interference
filter.
This must be especially considered if various
machines are connected to the same line.
Size differential cutout switches according
to the number of connected appliances. Install
a cable-protecting duct of outer diameter 20
mm between the cutout switch and the
appliance's power supply inlet. The inlet is
fitted with a pipe-securing nut which must
be fastened from inside the appliance after
having placed the stiff pipe. The machine is
supplied with a 3m long cord type FROR-
450/750V 4G of 4 sq.mm. Should it be
°
C
necessary to replace the cord, use one of the
°
C
same type and make sure it is flame-resistant
and duly protected. Once the cable has been
connected, fasten the nut inside the machine.
The ironer is tested in our factory so as to
conform with the cyclic direction of the
phases: R-S-T (A1-A2-A3) (L1-L2-L3). Do
not change the cyclic direction in order to
avoid damage to the appliance. Cyclic phase
connection is not important in appliances
equipped with an inverter, which sees to its
own adjustment.
direction as follows:
- Check that the basin is closed against the
roller. If it is, remove the inspection door by
using the appropriate key and turn the motor
handwheel clockwise until the basin is laid
against the roller. Then close the inspection
door again.
- Turn the wall cutout switch on and then
press the start push button; if the basin raises
the phases are connected correctly; otherwise
invert the wires of two incoming phases.
CAUTION: Inform the customer, user or
person in charge of the electrical wiring
inside the laundry room about the impor-
tance of the cyclic direction of the phases,
in order to prevent their accidental in-
version.
THE GUARANTEE IS NOT APPLI-
CABLE TO APPLIANCES WHOSE
DAMAGE OR FAILURE IS DUE TO
WRONG INSTALLATION
6. INFORMATION REGARDING THE
IRONER (see fig. 3)
6.1. DESCRIPTION OF THE IRONER
Rated
Threshold
The appliance is made up of the following
power-In current-Id
main parts, which appear on fig. 3:
1) Right side panel containing all moving
10 A
30 mA
16 A
30 mA
16 A
30 mA
2) Ironing roller, lined with ironing-suitable
16 A
30 mA
3) Heating basin, which presses against the
4) Lever pedal for automatic basin lowering
5) Emergency finger safety rod. When
6) Left side panel containing the second
7) Wooden board on which the laundry is
8) Key-locked inspection door for lifting
9) Temperature regulating device and
10) Start push button and green LED.
11) Stop push button and yellow LED.
12) "Heating on" pilot light.
13) Emergency push button.
14) Speed controller and display showing
15) Fumes outlet to be led outdoors through
a 60mm tube of smooth internal surface.
When connecting up be sure that no more
than 3 or 4 90° bends are installed, as this
could have adverse effects on extraction.
For good machine performance a length of
9
It is possible to manually check phase
INSTRUCTIONS
FOR THE USER
parts, electric control board and first basin-
moving gas spring.
fabric.
clothes to be ironed.
and roller start.
triggered it inverts roller rotation and lifts
the ironing basin.
basin-moving gas spring and optional the
extraction system (if any).
laid before being guided towards the
turning roller.
the basin by hand in case of an emergency.
display for basin temperature.
effective set value.