- check that the local power company has not
inverted your incoming three-phase supply ;
if this has happened, have the phases inverted
by our authorised technician or by a qualified
electrician.
If after checking or carrying out the above-
mentioned steps the fault persists, contact
your authorised assistance centre or our
dealer (see last page of this booklet).
8.2. SAFETY DEVICES
The machine features an electronic control
system that governs ordinary functions and
monitors some of the main settings of the
machine.
Apart from such electronic safety devices,
the appliance is also equipped with
electromechanical safety systems that
provide a high protection degree even in
case of failure of the electronic control.
The settings monitored by the machine,
which are indicated by flashing initials are
as follows:
AL1
SUPERTEMPERATURE
FAULTY PROBE
When a temperature beyond 210°C is
measured or when the probe is out of order
this alarm message is displayed and an
intermittent whistle-like sound is emitted
for one minute. The appliance remains like
that, still on but in alarm, until the temperature
drops below the alarm threshold. To eliminate
this problem it is also possible to switch the
appliance off and then on again.
AL2 THE OVERLOAD CUTOUT AT THE
EXTRACTION SYSTEM HAS TRIPPED
When malfunction or overheating is detected
in the extracting motor this alarm message is
displayed and an intermittent whistle-like
sound is emitted for one minute. The machine
is automatically switched off and the ironing
basin is lifted to its resting position. This
alarm can eliminated only by repairing and
if need be replacing the extracting system.
AL4 THE OVERLOAD CUTOUT AT THE
ROLLER MOTOR HAS TRIPPED
When malfunction is detected in the roller
motor this alarm message is displayed and
the alarm buzzer is actuated. The machine is
automatically switched off but the basin is
NOT brought to its resting position. To
eliminate this problem switch the appliance
off and then on again.
AL5 SAFETY DOOR
If the safety door is opened when the
appliance is on, this flashing message is
displayed. The machine is automatically
switched off but the basin is NOT brought to
its resting position. To exit this alarm status
just put the safety lid back in its normal
position. The position of the safety door is
monitored also when the machine is not
working but it is being energised (only yellow
light on).
All manuals and user guides at all-guides.com
AL6 BASIN UP TIME OUT
If after the pedal has been pressed the basin
does not reach its resting position within 10
seconds, this alarm message is displayed
and the alarm buzzer is actuated. The
appliance is automatically switched off and
only by being switched on again will it exit
this alarm status.
FURTHER SAFETY DEVICES
Apart from the electronically controlled
safety systems, the appliance is equipped
with a number of electromechanical
protection devices, i.e.:
1) SAFETY THERMOSTAT, manual reset
type, located at the rear of the machine, on
the control panel side. It cuts off power to the
heating elements as soon as temperature
reaches beyond 220°C. To reset the safety
thermostat unscrew its cap and press the
black pin with a tool until a "click" is heard.
OR
Then screw the cap back in place. Find out
what the cause of overheating was.
2) CUTOUT SWITCH
Disconnects the appliance from the power
mains.
3) SAFETY PUSH BUTTON
Switches the appliance off immediately at
any operating stage.
4) Line and auxiliary FUSES for total
protection of the electric system.
5) ELECTROMECHANICAL OVER-
LOAD CIRCUIT BREAKERS
manual reset type for the protection of the
built-in motors.
6) ISOLATION TRANSFORMER
Physically and electrically cuts off the
appliance from the power mains.
7)
FINGER SAFETY ROD against
accidental burns. It raises the basin and inverts
the rotating direction of the roller quickly
regardless of the roller driving speed.
8) SAFETY DOOR
To be used during black-out events to lift the
basin and so prevent damages to the laundry
and to the roller cover.
9) POWER SUPPLY CORD
3 m long, and built to the latest safety
standards.
WARNING: AS SOON AS A BUILT-IN
SAFETY DEVICE TRIPS, THE MACHINE
MUST BE IMMEDIATELY SWITCHED
OFF AND DISCONNECTED FROM THE
POWER MAINS THROUGH BOTH THE
BUILT-IN AND WALL CUTOUT
SWITCHES. HAVE THE CAUSE OF THE
ALARM BE FOUND AND SOLVED BY
AUTHORISED PERSONNEL BEFORE
12
RESUMING OPERATION.
8.3. SCHEDULED MAINTENANCE TO
BE CARRIED OUT BY TECHNICAL
STAFF
Any maintenance procedure must be carried
out by our authorised assistance service cen-
tres or qualified personnel only.
BEFORE CARRYING OUT ANY
SERVICING OR MAINTENANCE
PROCEDURE, MAKE SURE THAT
BOTH THE BUILT-IN AND THE
WALL CUTOUT SWITCHES ARE OFF.
Be very careful during maintenance. For no
reason whatsoever must safety devices be
ignored. Always use original spare parts.
Should doubts arise, call our technical office
immediately, referring to the model and serial
number found on the rating plate on the back
of your appliance.
- MONTHLY CHECK
Check the circumference of the roller using
a normal flexible tape measure. The circum-
ference of the roller must measure between
740 mm and 760 mm; homogeneously on
the whole roller length. If the circumference
is less than 740 mm, it is necessary to add
steel wool accordingly and maybe replace
the flannel layer. For these operations, please,
consult the relevant instructions.
- YEARLY CHECK
Grease the basin sliding guides with Teflon
grease.
Check that the safety devices are in perfect
working condition, that is, safety thermostat,
finger safety rod, emergency door micro-
switch, earth connection and circuit breaker
placed before the appliance.
Grease the two free wheels and the chain
with Teflon grease. Make sure the chain ten-
sion is adjusted correctly. If necessary, tighten
it by the bolts that fasten the reduction motor
unit.
The reduction motor unit does not need any
maintenance, because it is tight and greased
for life.
The springs do not need any maintenance
either.
Make sure that the connecting screws that
fasten the power supply wires to the remote
switches and the main cutout switch are
tight.
PRIOR TO RECONNECTING THE
POWER SUPPLY BY MEANS OF THE
BUILT-IN CUTOUT SWITCH AND
THE WALL CUTOUT SWITCH, FIT
ALL
PREVIOUSLY
PANELS BACK INTO PLACE.
- INSTRUCTIONS FOR REPLACING
THE ENTIRE COVER
Untie the cotton sheet and take off the entire
old cover as far as the roller metal sheet.
Place a spacer on each of the basin sliding
REMOVED

Publicidad