Descargar Imprimir esta página

Garland FUM 106 L Manual De Instrucciones página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6.4. VERIFICATION POINTS BEFORE FILLING THE
DEPOSIT
Check the machine and look for loose parts (screws,
nuts, housings, etc.) and damages. Tighten, repair
or replace the parts that you have found in poor
condition.
Make sure there are no leaks or leaks in the battery
and that the battery is properly secured in the
machine.
Check the state of the lance and nozzle and that it is
correctly positioned.
Do not use the machine if it is damaged or improperly
regulated.
6.5. FILLING THE DEPOSIT
Always place this machine in a flat and safe place
before carrying out the filling operation.
Always fill the tank with the machine turned off and
the On / Off switch in the "O" position (open)
Fill the tank carefully and slowly to prevent the
liquid from overflowing out of the tank. If the liquid
overflows, clean it quickly with a dry cloth and prevent
the liquid from reaching the battery or motor of
the machine. The liquid can damage the electrical
equipment of this machine, reducing the useful life of
the product.
If you are going to fill the tank with a mixture of liquids
or a mixture of liquids and soluble products, always
make the mixture before filling the tank. Do not use
the tank to make the mixes inside.
Do not use the fumigator to spray liquids or liquid
mixtures that are above 45ºC or less than 5ºC.
6.6. START UP AND STOPPING THE MACHINE
WARNING: The pump of this machine must not work
in a vacuum (without liquid). Never start this machine
without liquid to be sprayed in the tank.
6.6.1. SWITCHED ON
Set the On / Off switch to the "I" position
6.6.2. STOP
Set the On / Off switch to the "O" position
6.7. LOW BATTERY LOAD INDICATOR
When the battery of your fumigator has little charge,
the output power of the liquid will be less, and you will
have to charge the battery.
6.8. VERIFICATION POINTS AFTER START-UP
It is important to pay attention to possible loose parts
and temperature of the machine. If you detect any
anomaly in the machine, stop immediately and check
it carefully. In case of any anomaly or problem take
the machine to the technical service to repair it. In no
27/92
English
ON
OFF

Publicidad

loading

Este manual también es adecuado para:

Fum 106 l-v21