Electrical
Risk of electric shock . Can shock, burn or kill. Disconnect power before working on pump, motor,
pressure switch, or wiring.
Risk of fire . Never wire a 115 volt motor to a 230 volt line.
Motor Switch Settings
Dual-voltage motors (motors that can operate at either
115 or 230 volts), are set at the factory to 230 volts.
Use the instructions to set your motor to match your
power source.
Remove Motor End Cover
When connecting to 115 volts, follow the
procedure below.
You will need to remove the motor end cover to change
the voltage setting.
End Cover Screws
Motor End Cover
Figure 3 - Removing Motor End Cover
Your motor terminal board (located under the motor end
cover) should look like Figure 4.
Ground Wire
Terminal
Power Supply
Terminals
Figure 4 - Voltage set to 230 volts, Dial Type; turn dial to
select 115 volts. Insert tool in slot to turn dial.
Se lecting 115 volts with the Dial Type Voltage Selector
To change to 115 volts:
4693 1011
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in
the dial window.
3. Attach the power lead wires to the power lead
terminals. Make sure the wires are secure.
4. Attach the ground wire to the green ground screw.
5. Reinstall the motor end cover.