1 Tool fails to
startup or has
shut down due
to the unit being
connected to a
power source
whose voltage is
either too high or
too low.
Flash
2 Tool has shut
down due to a
voltage signal
read error that
occurred from
the unit's power
cord being
plugged in and
out at short
intervals.
(Circuit protection
function)
Sensor signal read
Flash
error.
(Control monitoring
function)
GREASE REPLACEMENT
This Rotary Hammer is of full air-tight construction to protect
against dust and to prevent lubricant leakage.
Therefore, this Rotary Hammer can be used without lubrication
for long periods. Replace the grease as described below.
Grease Replacement Period
After purchase, replace grease after every 6 months of
usage. Ask for grease replacement at the nearest authorized
Service Center.
MAINTENANCE AND INSPECTION
1. Inspecting the drill bits
Since use of a dull tool will cause motor malfunctioning
and degraded effi ciency, replace the drill bit with new
ones or resharpen them without delay when abrasion is
noted.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that
they are properly tightened. Should any of the screws be
loose, retighten them immediately. Failure to do so could
result in serious hazard.
3. Maintenance of the motor
The motor unit winding is the very "heart" of the power
tool.
Exercise due care to ensure the winding does not
become damaged and/or wet with oil or water.
4. Replacing supply cord
If the replacement of the supply cord is necessary, this
has to be done by the manufacturer of this agent in order
to avoid a safety hazard.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
1 Connect the unit
to a power supply
matching the input
voltage specifi ed
on the nameplate.
Press the rotation
speed selector
switch to recover.
2 Allow for an interval
of 3 seconds or
more when plugging
the power cord
in and out. Press
the rotation speed
selector switch to
recover.
Press the rotation
speed selector switch
to recover. Repair may
be required if this error
continuously occurs.
5
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
English