TECHNICAL SPECIFICATION
Power supply voltage
Max. absorbed power
during air conditioning
Refrigerant
Cooling capacity
LIMIT CONDITIONS
Room temperature for
air conditioning
Transport, filling, cleaning, recovery and disposal
of refrigerant should be performed by a technical
service centre appointed by the manufacturer
only. The appliance should be disposed of by a
specialist centre appointed by the manufacturer
only.
NEVER TRANSPORT OR TURN THE APPLIANCE
UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS,
WAIT 6 HOURS BEFORE TURNING THE APPLIANCE
ON, 24 HOURS IS RECOMMENDED. (After the unit has
been on its side, oil needs to return to the compressor to
ensure proper function. Without allowing the unit this
time (6-24 hours) The unit may function for only a short
time, and then the compressor will break down from lack
of oil).
This appliance is equipped with a 3 prong grounded
plug. The plug must be connected into an outlet that is
properly installed and grounded in the accordance with
all local codes and ordinances. Do not modify the plug
provided with the appliance. If it will not fit the outlet,
have a proper outlet installed by a qualified electrician or
relocate the unit to a proper outlet.
If the household electrical supply does not meet the
above specifications, or if you are not sure your home
has an effective electrical ground, have a qualified
electrician or your local electrical utility company check
it and correct any problems.
Technical specifications
see rating label
"
"
"
70 ÷ 95°F 21 ÷ 35°C
12
SAFETY PLUG
The appliance is fitted with a safety plug to protect the
power cable.
If power is cut off, unplug from the outlet and make sure
the power cable is undamaged.
If the cable is damaged, call the service center
immediately.
If power cuts off frequently and the power cable is
undamaged, contact a qualified electrician.
OPERATION OF THE SAFETY PLUG
If the safety device incorporated in the plug trips and cuts
off the power supply, check that the power cable and
plug are not damaged.
If the power cable is undamaged, to restore operation
press the " RESET" button.
To verify correct operation of the plug, press the
"TEST" button periodically and make sure the appliance
disconnects. If this is not the case, contact the service
center.
To restore operation, press the " RESET" button.
en