Descargar Imprimir esta página

GYS toparc MT-125 Manual Del Usuario página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
SET UP
TORCH CONNECTION REQUIREMENT
The cutting machine must be switched off.
TORCHES EQUIPMENT
The torch must be fitted with the appropriate consumables, selected based on the application and selected current.
Using the wrong consumables will result in poor cutting, excessive use of consumables and possibly prevent the machine from working.
MT-125 – CUTTING-GOUGING :
PRECISION CUT
039322 (x1)
45A
039230 (x1)
039216 (x1)
Protective
Shield
039247 (x1)
039223 (x1)
Shield
Protective
039254 (x1)
039216 (x1)
Protective
Shield
shroud
MT-125 / AT-125
039315 (x5)
45A
039162 (x5)
45A
039179 (x5)
65A
shroud
039186 (x5)
85A
Tailpipe
029193 (x5)
105A
039209 (x5)
125A
shroud
Tailpipe
039261 (x5)
65-85A
Tailpipe
Insert the torch connector (A) in the female connector (E) and screw the
part B. Make sure the torch is tight enough.
To remove the torch, unscrew as shown below.
039155 (x5)
039131 (x1)
Electrode
Di user
039155 (x5)
039148 (x1)
Electrode
Di user
039155 (x5)
039131 (x1)
Electrode
Di user
85A TRI
125A TRI
039506 - 6 m
039513 - 12 m
125A TRI
039506 - 6 m
039513 - 12 m
85A TRI
125A TRI
039506 - 6 m
039513 - 12 m
EN
9

Publicidad

loading

Este manual también es adecuado para:

Toparc at-125