Descargar Imprimir esta página

voestalpine bohler SABER 40 CHP Manual De Instrucciones página 28

Ocultar thumbs Ver también para bohler SABER 40 CHP:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
6 TROUBLESHOOTING
The repair or replacement of any parts in the
system must be carried out only by qualified
personnel.
The repair or replacement of any parts in the system by
unauthorised personnel will invalidate the product warranty.
The system must not be modified in any way.
The manufacturer disclaims any responsibility if the user
fails to follow these instructions.
The system fails to come on (green LED off)
Cause
No mains voltage at the socket.
Solution
Check and repair the electrical system as needed.
Use qualified personnel only.
Cause
Faulty plug or cable.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Line fuse blown.
Solution
Replace the faulty component.
28
5.
Remove the lock nut from
card P .C. board 15.14.406
and pull out the cable.
6.
Release the hose clamp and
pull out the hose.
7.
Remove the cable clamp
and gusset.
8.
Pull out the torch from the
outside.
Cause
Faulty on/off switch.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
No output power
Cause
Faulty torch trigger button.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
The system has overheated (temperature alarm -
yellow LED on).
Solution
Wait for the system to cool down without switching
it off.
Cause
Incorrect earth connection.
Solution
Earth the system correctly.
Read the paragraph "Installation ".
Cause
Mains voltage out of range (yellow LED on).
Solution
Bring the mains voltage within the power source
admissible range.
Connect the system correctly.
Read the paragraph "Connections ".
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
Incorrect output power
Cause
Faulty potentiometer for the adjustment of the cut-
ting current.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
No pilot arc striking
Cause
Faulty torch trigger button.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Worn nozzle and/or electrode.
Solution
Replace the faulty component.
Cause
Air pressure too high.
Solution
Adjust the air flow.
Read the paragraph "Installation".
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
No cutting arc striking
Cause
Incorrect earth connection.
Solution
Earth the system correctly
Read the paragraph "Installation".

Publicidad

loading