Electrical Wiring

Wiring Procedure

WARNING! Electrical wiring should be performed ONLY by a licensed electrician
in compliance with local, state, and national electrical code NEC/ANSI/NFPA 70,
NFPA30, and NFPA 30A, as appropriate to the intended use of the pump.
Threaded rigid conduit, sealed fittings, and conductor seal should be used. The
pump must be properly grounded. Improper installation or use of this pump can
result in serious bodily injury, or death!
CAUTION! All pumps should operate at the rated nameplate voltage. Power
should be supplied to the pump from a 20 amp circuit breaker. No other
equipment should be powered by this circuit. Wiring must be of sufficient size to
carry the correct current for the pump. Voltage drop will vary with distance to
pump and size of wire; refer to the National Electrical Code (NEC), or local codes,
for voltage drop compensation to be sure you are using the correct size wire for
your application.

AC Receptacle

AC pumps come wired two different ways: 110 VAC pumps are equipped with a conventional
110 VAC 3-prong grounded plug that can be inserted into any conventional grounded
receptacle. The receptacle circuit must be protected with a 20 amp circuit breaker.
230 VAC pumps come with a power cord (no plug) for direct wiring installations.
WARNING! THIS PRODUCT MUST BE GROUNDED! DO NOT defeat the
ground prong on the plug by using an adapter, or otherwise modifying the plug.
DO NOT plug this appliance into an ungrounded receptacle.

DC Wiring

DC pumps are connected to the power source by way of the power cord. The power cord
terminates in red and black alligator clamps; connect the red clamp to the positive post of the
DC power source, and the black clamp to the negative post.

Operating Instructions

1.
If so equipped, reset Meter to "0" (do not reset while in use as this can cause damage to
the meter).
2.
Remove dispensing nozzle from nozzle boot.
3.
Move the switch lever to the "ON" position to power the pump.
4.
Insert the dispensing nozzle into the container to be filled.
5.
Operate the nozzle to dispense fluid; release nozzle when the desired amount of fluid
has been dispensed.
6.
Move switch lever down to the "OFF" position to turn off the pump.
7.
Remove the dispensing nozzle from the container and store it in the nozzle boot.