3.1. MODE BUTTON
„ Press the MODE button to select AC/DC voltage, frequency, resistance, diode test, continuity or
capacitance, temperature.
„ For voltage, current and capacitance measurement, make a long press on the MODE key to activate
or deactivate the relative mode.
3.2. RANGE BUTTON
„ When the clamp meter is first turned on, it automatically goes into auto-ranging.
„ This automatically selects the best range for the measurements being made and is generally the
best mode for most measurements.
„ For measurement situations requiring that a range be manually selected, perform the following:
„ Press the RANGE button, the AUTO display indicator will turn off.
„ Press the RANGE button to step through the available ranges until you select the range you want.
„ Press and hold the RANGE button for 2 seconds to exit the Manual Ranging mode and return
to Auto Ranging.
3.3. MAX/MIN BUTTON
„ Press the MAX/MIN button to activate the MAX/MIN mode, the MAX indicator will appear on the
LCD display, the clamp meter will display and hold the maximum reading and will update when a
higher maximum occurs.
„ Press the MAX/MIN button again to view the lowest reading, the MIN indicator clamp meter will
appear on the LCD display, the clamp meter will display and hold the minimum reading and will
update when a lower minimum occurs.
„ Make a long press on the MAX/MIN button to end MAX/MIN and return to normal operation.
Note: The clamp meter does not autorange when the MAX/MIN mode is active, the display will read OL if
the range is exceeded. When this occurs, exit MAX/MIN and use the RANGE button to select a high range.
MAX/MIN does not work on Frequency, Duty Cycle, Diode Test, Continuity and Capacitance.
3.4. HOLD AND FLASHLIGHT BUTTON
„ Press the HOLD/
„ Press the HOLD/
3.5. AUTO POWER OFF
The auto off feature will turn the clamp meter off after 15 minutes.
To disable the auto power off feature, hold down the MODE button and turn the clamp meter on.
3.6. LOW BATTERY INDICATION
The
symbol will appear in the lower left corner of the display when the battery voltage becomes low.
Replace the battery when this appears.