• EN 62311:2008 | EN 50665:2017 | EN 50385:2017: RF exposure
• EN 301 489-1 v2.2.0 (2017-03): Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services;
Part 1: Common technical requirements
• EN 301 489-17 V3.2.0 (2017-03): Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services;
Part 17: Specific conditions for 2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment
• EU 2015/863 (RoHS 3): Declaration of Compliance – EU Directive 2015/863; Reduction of Hazardous Substances (RoHS)
This device is a 2.4 GHz wideband transmission system (transceiver), intended for use in all EU member states and EFTA countries, except in France and Italy where restrictive use
applies.
In Italy the end-user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links and/or for supplying
public access to telecommunications and/or network services.
This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range of 2454 – 2483.5
MHz. For detailed information the end-user should contact the national spectrum authority in France.
CE DECLARATION
Hereby, DeVilbiss Healthcare LLC, declares that this Portable Oxygen Concentrator device with Bluetooth is in compliance with the essential requirements and other relevant provisions
of Directive 2014/53/EU. The declaration of conformity may be consulted at https://drivemedical.com/us/en/service/declarationconformity.
The Bluetooth
word, mark, and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by DeVilbiss is under license. Other trademarks and trade names are those of their respective
®
owners.
125x-BT Series Portable Oxygen Concentrator Basic Pneumatic Diagram
NOTE– There are no operator-detachable parts.
Air Intake
(both sides)
Exhaust
(both sides)
WARRANTY
Drive DeVilbiss Healthcare warrants the Drive DeVilbiss iGo2 Portable Oxygen Concentrator under the conditions and limitations stated below. Drive DeVilbiss warrants this equipment to
be free from defects in workmanship and materials for five (5) years from date of factory shipment to the original purchaser (typically the healthcare provider) with the exceptions of the
Compressor (warranted for 3 years), Sieve Beds (warranted for 1 year), and Battery (warranted for 1 year). The carry case is excluded from this warranty. These warranties are limited to
the Buyer of new equipment purchased directly from Drive DeVilbiss, or one of its Providers, Distributors, or Agents. Drive DeVilbiss' obligation under this warranty is limited to product
repair (parts and labor) at its factory or at an Authorized Service Center. Items that undergo normal wear and tear are not covered under warranty.
WARRANTY CLAIMS SUBMISSIONS
The original purchaser must submit any warranty claim to Drive DeVilbiss or to an Authorized Service Center. Upon verification of the warranty status, instructions will be issued. For all
returns, the original purchaser must (1) properly package the unit or parts in a Drive DeVilbiss approved shipping container, (2) properly identify the claim with the Return Authorization
Number, and (3) send the shipment freight prepaid. Service under this warranty must be performed by Drive DeVilbiss and/or an Authorized Service Center.
NOTE– This warranty does not obligate Drive DeVilbiss to provide a loaner unit during the time that an oxygen concentrator is undergoing repair.
NOTE– Replacement components are warranted for the unexpired portion of the original Limited Warranty.
This warranty shall be voided, and Drive DeVilbiss shall be relieved of any obligation or liability if:
• The device has been misused, abused, tampered with, or used improperly during this period.
• Malfunction results from inadequate cleaning or failure to follow the instructions.
• The equipment is operated or maintained outside the parameters indicated in the Drive DeVilbiss operating and service instructions.
• Unqualified service personnel conduct routine maintenance, servicing, or repairs.
• Unauthorized parts or components (i.e., regenerated sieve material) are used to repair or alter the equipment.
• Unapproved filters are used with the unit.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED
TO THE DURATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. THIS IS THE
EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION
IS PERMITTED BY LAW. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE LIMITATION OR EXCLUSION OF
CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
NOTE– International warranties may vary.
ORDERING AND RETURNING PARTS
Drive DeVilbiss Customer Service Contact Information
Customer Service (USA): 800-338-1988
International Department: 814-443-4881 / DHCinternational@DeVilbissHC.com
ORDERING NON-WARRANTY REPLACEMENT PARTS
Order non-warranty parts and literature from your Drive DeVilbiss provider.
EN - 20
Oxygen Outlet Port
(cannula connection)
A-125B