6
POTENTIOMETER ADJUSTMENT
7
STARTING UP
Final checks
Following installation and programming, start up the
gate and check all the devices installed.
1 Check the correct operation of the key commands
(transmitter, pushbutton and wall key).
See "Functioning modes" on page 20.
2 Check the correct operation of the safety devices
(photocells or mechanical strips).
See
"Obstacle
detection
page 21.
If the system does not work correctly, find out
why and put it right (see section "Failure
diagnosis" on page 30).
Regulation of garage lighting time (T.LG)
If the garage lighting circuit has been connected to the
control panel, regulate the time which the lights shall
remain on using T.LG.
Minimum value: 3 seconds; maximum value: 90
seconds
Open gate standby time (T.E.)
If automatic or alternative automatic functioning mode
has been programmed, regulate T.E. to adjust the
standby time with the gate open (before automatic
closing begins).
Minimum value: 0 seconds; maximum value: 90
seconds
Torque regulation (P.M)
Correct
importance to prevent injury and damage.
Increased torque produces a more violent
impact.
Adjust the torque limitation potentiometer (P.M) at
the lowest value possible, compatible with the proper
operation of the gate.
User instruction
1 Instruct the user with regards to the use and
2 Signpost
functioning"
on
PROGRAMMING AND STARTUP
torque
adjustment
maintenance of the installation and provide him/her
with the user guide.
the
gate,
showing
automatically and indicating how to operate it
manually.
Where
appropriate,
operation is using the remote control.
Control board AM600S-AM606S
is
of
vital
that
it
opens
indicate
that
29