1 Connect the control panel power supply (SW1 in
ON).
2 Close the leaf of the gate by pressing PUL1.
3 Place DIP1 and DIP4 in "ON"; DIP2, DIP3, DIP5 and
DIP6 in "OFF".
DL3 lights up.
4 Select the required code in the transmitter.
5 Press the channel to be used for total opening.
If programming has been carried out correctly,
DL2 flashes.
6 Place DIP1 and DIP4 in "OFF" (DL2 and DL3 will go
off).
7 Disconnect and reconnect the panel power supply.
1 Connect the control panel power supply (SW1 in
ON).
2 Close the leaf of the gate by pressing PUL1.
3 Place DIP1 and DIP6 in "ON"; DIP2, DIP3, DIP4 and
DIP5 in "OFF".
DL3 lights up.
4 Select the required code in the transmitter.
5 Press the channel to be used for pedestrian opening.
If programming has been carried out correctly,
DL2 flashes.
6 Place DIP1 and DIP6 in "OFF" (DL2 and DL3 will go
off).
7 Disconnect and reconnect the panel power supply.