Descargar Imprimir esta página

Haier HAFRSJ64MB1 Manual De Instrucciones página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85
The induction hob is equipped with a self diagnostic function. With this test the technician is able to check the function
of several components without disassembling or dismounting the hob from the working surface.
Troubleshooting
1)
Failure code occur during customer using & Solution;
Failure code
E1
Supply voltage is above the rated voltage.
E2
Supply voltage is below the rated voltage.
E3
High temperature of ceramic plate sensor . 1#
E4
High temperature of ceramic plate sensor . 2#
E5
High temperature of IGBT . 1#
E6
High temperature of IGBT. 2#
Ceramic plate temperature sensor failure- -short
F3/F6
circuit. (F3 for 1#,F6 for2#)
Ceramic plate temperature sensor failure--open
F4/F7
circuit. (F4 for 1#,F7 for2#)
Ceramic plate temperature sensor
F5/F8
failure—invalid . (F5 for 1#,F8 for2#)
Temperature sensor of the IGBT failure. short
F9/FA
circuit/open circuit for 1#
Temperature sensor of the IGBT failure. short
FC /FD
circuit/open circuit for 2#
Problem
Auto-Recovery
)
)
)
)
)
)
)
)
No Auto-Recovery
)
)
)
EN-18
Solution
Please inspect whether power supply is normal.
Power on after the power supply is normal.
Wait for the temperature of ceramic plate return
to normal.
Touch "ON/OFF" button to restart unit.
Wait for the temperature of IGBT return to
normal.
Touch "ON/OFF" button to restart unit.
Check whether the fan runs smoothly;
if not , replace the fan.
Check the connection or replace the ceramic
plate temperature sensor.
Replace the power board.

Publicidad

loading