3M 26878 Manual Del Propietário página 13

Ocultar thumbs Ver también para 26878:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GENERAL SET UP AND SPRAY GUN USE - PRESSURE
Note: Complete steps below before connecting spray gun to air source.
Attaching the Atomizing Head
1.
Pull trigger back and hold.
2.
Slide the atomizing head over the fluid
needle and push towards the spray gun
body making sure locking collar is in the
"+ configuration" with locking lugs at the
counter clockwise stop at 3 and 9 o'clock.
3.
Secure the atomizing head by rotating the
retainer ring, clockwise until the retainer ring
tabs are locked in the "X configuration".
Removing the Atomizing Head
1.
Fully pull trigger back and hold.
2.
Rotate the locking collar counter-clockwise
3.
Pull the atomizing head away from the gun
body to remove.
11 11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2677826832

Tabla de contenido