5.2. Test Extraction / Retraction of Lifeline
and Fall Arrest Brake
i.
Inspect and confirm lifeline extraction and retraction. Pull out the full length of lifeline
and allow it to retract back into the case in a controlled manner. The lifeline should
retract freely with no obstructions.
ii.
Confirm the fall arrest brake engages by sharply pulling down on the snap hook. The
brake should engage and remain engaged until the tension is released
5.3. Test the Retrieval Mechanism
i.
Engage the retrieval mechanism by following the instructions set out in Section 6.3 of
this manual.
ii.
Rotate the crank arm clockwise and confirm the lifeline extracts out of the housing.
Keep tension on the lifeline for proper extraction.
iii. Rotate the crank arm anticlockwise and confirm the lifeline retracts into the housing.
Keep tension on the lifeline for proper extraction.
iv.
Disengage the retrieval mechanism and return the SAVER to fall arrest mode by
following the instructions in Section 6.1 of this manual.
!
Do not use this product as a material hoist.