INSTALLATION
Electrical Connections
Electrical Connections
Risk of severe injury or death by electrical shock.
• Always disconnect the electrical power before touching the pump, discharge or electrical plug when water
is present in the area. Failure to do so can result in serious bodily injury and/or property damage.
• Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI)
device if required by code.
• Be sure the electrical connection cannot be reached by rising water. Under no circumstances should the
junction box be located where it may become flooded or submerged by water.
• Connect the power cord to a constant source of power matching the voltage specified on the pump
nameplate.
• Always connect pump to grounded receptacle.
• Connect or wire the pump to its own circuit.
• The fuses or circuit breaker should be of ample capacity in the electrical circuit.
• If using an extension cord, make sure its connection with the power cord is not in water.
NOTE: If the power cord is damaged, the whole unit must be replaced.
Troubleshooting
Problem
Pump is not plugged in
Circuit breaker is off or
Pump does not
fuse is removed
turn on
Defective switch
Defective motor
Defective switch
Pump is air locked
Pump will not shut
Liquid inflow matches or
off
exceeds pump output
capacity
Frozen water in discharge
hose
Lift too high for pump
Inlet to impeller plugged Pull pump and clean.
Pump runs but
does not
Outlet flow is blocked
discharge liquid
Frozen water in discharge
hose
Lift too high for pump
Low voltage, speed too
slow
Pump does not
deliver rated
Impeller or discharge
capacity
pipe is clogged
Discharge hose diameter
is too small
For technical assistance, parts, or repair, please contact:
800.701.7894 | littlegiant.com
993944 Rev. 003 01/22
Probable Causes
Corrective Action
Plug in the pump.
Turn on circuit breaker or replace fuse.
Replace pump.
Replace pump.
Replace pump.
Shut power off for approximately 1 minute, then restart. Repeat
several times to clear air from pump.
Multiple or larger pump required.
Thaw hose or replace hose.
Check rated pump performance.
Check outlet tubing to ensure that it is not kinked or blocked.
Clear blocked tubing of slime and debris. Clean inlet and outlet
piping.
Thaw or replace hose.
Check rated pump performance.
Check that supply voltage matches nameplate rating.
Pull pump and clean. Check pipe for scale or corrosion.
Replace discharge hose with larger diameter hose.