Descargar Imprimir esta página

Hatco HBG Serie Manual De Instalación Y Operación página 12

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
TROUBLESHOOTING GUIDE
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Symptom
Unit too hot.
Temperature control set too high.
Temperature control stuck in the ON position.
Unit plugged into incorrect power supply.
Unit not hot enough.
Temperature control set too low.
Location of unit is susceptible to air currents (air
conditioning ducts or exhaust fans).
Unit not working at all.
Unit not plugged in.
Unit not turned on.
Power I/O switch is not functioning.
Heating element is burned out.
Temperature control is defective.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com, select the Support pull-
down menu, and click on "Find A Service Agent"; or contact the Hatco Parts and Service Team at:
Telephone: +1-414-671-6350
e-mail:
support@hatcocorp.com
OPTIONS AND ACCESSORIES
Handles (HBG Model)
The following handles are available for the HBG unit.
HANDLE-18-SS .... Rounded stainless steel handles
HANDLE-18-BLK .. Designer black powdercoated rounded
stainless steel handles
The handles are field retrofittable and are installed onto each
end of the unit using the following procedure.
On each end of the unit:
1. Remove the three nuts located on the underside of the
glass surface support ring.
2. Align the three holes on the handle with the three studs on
the support ring, and position the handle on the studs.
3. Replace the three nuts onto the studs, and tighten securely.
Probable Cause
12
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, setup, or maintenance.
Corrective Action
Adjust temperature control to a lower setting.
Contact Authorized Service Agent or Hatco for assistance.
Verify with qualified personnel that power supply matches unit
specification.
Adjust temperature control to a higher setting.
Block air currents or relocate unit.
Plug unit into proper power supply.
Move Power I/O (on/off) switch to the I (on) position.
Contact Authorized Service Agent or Hatco for assistance.
Handle
Handle Installation
Support
Ring
Stud
Nut
Form No. HBGCEM-0520

Publicidad

loading