102 mm Adjustable Legs (HBG Model)
Use the following procedure to install 102 mm (4") adjustable
legs in place of the rubber feet on an HBG unit.
NOTE: 102 mm (4") legs are included with models greater than
1041 mm (36") in width.
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, setup, or maintenance.
NOTICE
Do not lay unit on the side with the control panel or
damage to unit could occur.
1. Turn off the unit, unplug the power cord, and allow the unit
to cool.
2. Carefully turn the unit upside down and lay the unit on a flat
surface. Make sure to cover the surface with something to
prevent scratching the glass.
3. At each corner of the base, remove the foot screw and
rubber foot.
Installing the 4" Legs
4. At each corner of the base, screw a 4" leg into the bottom
of the base.
NOTE: The feet on the 4" legs are adjustable for leveling the
unit. Use a 5/8" (16 mm) open-end wrench to make
leveling adjustments once the unit is placed in its final
position.
149 mm
(5-7/8")
174 mm
(6-7/8")
98 mm
(3-7/8")
Front View of Cutout
Form No. HBGCEM-0520
4" Leg
IMPORTANT NOTE:
Make sure the installation
location provides enough
room
connections to the control
enclosure.
162 mm
(6-3/8")
Remote Mounted Control Panel Installation Dimensions
OPTIONS AND ACCESSORIES
Remote Mounted Control Panel (HBGB)
A flush-style remote mounted control panel is available as a
factory-installed option for the HBGB unit. Install the control
panel on-site using the following procedure.
ELECTRIC SHOCK HAZARD: Remote mounted control
panel must be mounted on a vertical wall and installed
in vertical position. Mounting control panel in horizontal
position may result in collection of liquids and lead to an
electric shock.
The remote mounted control panel should be installed
outside of the heat zone. Locating the control panel
inside the heat zone will cause the control(s) to overheat,
malfunction, and fail.
Do not modify wiring or cut thermostat capillary wire on
control box to increase semi-remote mounting distance.
Cutting the thermostat capillary wire will cause the unit
to overheat and may damage the unit as well as the
surrounding countertop.
NOTE: A qualified electrician is recommended for installing the
remote mounted control panel.
1. Prepare cutout and pre-drill screw holes.
2. Remove trim cover from control panel assembly.
3. Position control panel into opening through the backside.
4. Secure control panel to surface using screws
(not supplied).
5. Plug the control panel into a properly grounded electrical
outlet of the correct voltage, size, and plug configuration.
Refer to the SPECIFICATIONS section for details.
6. Reinstall trim cover.
NOTE: Units are equipped with a 914 mm (3'), 1829 mm (6'),
or 3048 mm (10') flexible conduit connecting the control
panel to the unit.
Indicating Temperature Control (ITC)
for
electrical
Trim Cover
Side View of Installed Enclosure
13
WARNING
NOTICE
121 mm (4-3/4")
Thermostat Enclosure
102 mm (4")
Control Enclosure
Mounting Surface