Descargar Imprimir esta página

Hatco HBG Serie Manual De Instalación Y Operación página 14

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
OPTIONS AND ACCESSORIES
Power ON/OFF Switch
The remote mounted control panel is equipped with a power
ON/OFF switch. Move the power ON/OFF switch to the ON
position to turn on the unit. The indicator light in the switch
glows when the unit is on.
Adjusting the Temperature Control
Turn the temperature control clockwise to increase
the temperature setpoint. Turn the temperature control
counterclockwise to decrease the temperature setpoint.
Temperature Control
Power I/O (on/off) Switch
Remote Mounted Control Panel
Changing the Setpoint Temperature — Digital
Temperature Controller
Units equipped with a digital temperature controller will heat
up to the setpoint temperature automatically when they are
turned on. Use the following procedure to change the setpoint
temperature.
NOTICE
Built-in units must not have a setpoint temperature higher
than 200°F (93°C). Temperatures exceeding 200°F (93°C)
will damage unit and void warranty.
NOTE: The temperature shown on the display may be inaccurate
when unit temperature is below 130°F (54°C).
1. Press the
key three times. The current setpoint
temperature will be shown on the TEMPERATURE
display ("SP" will be shown after the second press).
2. Press the
key or
the setpoint temperature.
3. Press the
key to lock in the new setpoint temperature.
The TEMPERATURE display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
key within 10 seconds to change
Up Arrow
SET Key
Digital Temperature Controller
Changing Fahrenheit and Celsius Setting — Digital
Temperature Controller
Use the following procedure to change between Fahrenheit and
Celsius on the display.
1. Press the
key once. Either an "F" for Fahrenheit or "C"
for Celsius will be shown.
2. Press the
key or
between "F" (Fahrenheit) and "C" (Celsius).
3. Press the
key three times to lock in the new setting.
The TEMPERATURE display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
White Glass
White glass is available as a factory installed option instead of
the standard black glass.
14
Key
Down
Arrow
Key
Display
key within 10 seconds to change
Form No. HBGCEM-0520

Publicidad

loading