Settings
Code C4
Electrical compensation of residual unbalance, if
any, in the clamping means
Measurement with increased precision (this mode
cannot be transferred into the permanent memory).
Compensation has to be cancelled and carried out
once again when the clamping means is exchanged.
Resetting the status to 0 cancels the compensation of
adaptor unbalance.
The compensation is cancelled by calibration, or
readjustment of the machine, by optimization, or when
the machine is turned off
Code C5
Braking of the wheel when the wheel guard is
opened during the measuring run
0 =
No braking
THE WHEEL ROTATES WHEN THE WHEEL GUARD
IS OPEN.
MAKE SURE THAT THE WHEEL IS NOT BLOCKED
BY A TOOL OR SIMILAR ITEM.
WEAR SAFETY GOGGLES AND TIGHTLY FITTING
WORKING CLOTHES.
1* =
Braking
The selected mode of operation can be transferred to
the permanent memory.
Code C6
Number of revolutions per measuring run 5 to 25
revolutions possible, factory–set to 10*
Note
Reducing the number of measurement revolutions will
reduce the accuracy of measurement. The selected
mode of operation can be transferred to the permanent
memory.
* = Factory adjusted mode