Descargar Imprimir esta página

Samoa 542 011 Manual De Instrucciones página 3

Publicidad

RECOMMENDED SEQUENCE OF OPERATION / SECUENCIA RECOMENDADA PARA OPERAR
TYPICAL INSTALLATION / CONEXIÓN TIPO DE LA BOMBA
EN
Figure 2 is a typical installation shown with all the recommended
accessories for the pump to operate correctly.
NOTE: The compressed air supply must be set between 3 and 12 bar (40
– 174 psi), being 7 bar (98 psi) the recommended pressure. An air
closing valve must be installed, in order to be able to close the
compressed air line at the end of the day (If the air inlet not is closed and
there is a leakage in some point of the ink outlet circuit, the pump will
start automatically, emptying the container or dry-running).
A título informativo, se muestra en la figura 2 una instalación típica con
EN
ES
POS
A
B
C
D
E
F
G
H
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
E
D
F
Fig. 2
DESCRIPTION
Air shut off valve
Filter regulator
Air hose
Quick coupling
Connection nipple
Pump
Ink hose
Ink shut off valve
ES
todos los elementos recomendados para su correcto funcionamiento.
NOTA: La presión de alimentación de aire debe estar comprendida entre
3 y 12 bar (40 – 174 psi) siendo 7 bar (98 psi) la presión recomendada.
Es aconsejable instalar, asimismo, una válvula de cierre para poder cerrar
la alimentación de aire al final de la jornada. (En caso de roturas o fugas
en la salida de tinta, si la alimentación de aire no está cerrada, la bomba
se
pondría
en
marcha
automáticamente,
completamente el depósito o funcionar en seco).
C
B
A
G
H
Válvula de corte de aire
Manguera de tinta
Válvula de cierre de tinta
pudiendo
DESCRIPCIÓN
Filtro regulador
Manguera de aire
Enchufe rápido
Conector rápido
Bomba
R. 10/18 854 808
vaciarse
3

Publicidad

loading