TESTING FOR LEAKS
4. PUSH ON / OFF SWITCH
Begins 5-minute vapor cycle
VAPOR INDICATOR:
Amber Light: Vapor is Generating
Flashing Amber Light: Open Circuit, See Troubleshooting Section
No Amber Light: No Vapor Generating
Turn Flow Control Knob counter-clockwise to release vapor/pressure
Flow Meter indicates flow and measures leak size
Use provided Inspection Light to locate leaks
Perform repair(s) as needed
VERIFY REPAIRS
5. PERFORM DECAY / LEAK DOWN TEST
Pressurize the sealed system
Lock out system by turning Flow Control Knob clockwise to the fully closed position
OBSERVE PRESSURE GAUGE FOR DECAY:
Pressure Holds: No leaks, Repair is complete
Pressure Decreases:
Leak(s) exist, Repeat Steps 4 & 5 until all repairs are complete
NOTE: Not all systems are designed to be 100% sealed
MDSMOKELITE
7