ELECTRICAL AND CONTROL SETTINGS
Output - Setting before shipment
Mark
Description
O1
Output 1
O2
Output 2
O3
Output 3
O4
Output 4
O5
Output 5
O6
Output 6
O7
Output 7
O8
Output 8
O9
Output 9
O10
Output 10
O11
Output 11
O12
Output 12
O13
Output 13
O14
Output 14
O15
Output 15
Default settings
o - 01
(3WV SWP)
o - 02
(WP3)
o - 03
(Boiler combination)
o - 04
(Solar out)
o - 17
(DHW Electric Heater)
o - 18
(3WV DHW)
o - 19
(Mixing valve Close)
o - 20
(Mixing valve Open)
o - 21
(WP2)
o - 22
(3WV Cooling)
o - 08
(WP1)
o - 23
(Act1)
o - 24
(Act2)
o - 25
(Act3)
o - 26
(Act4)
Available output codes
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 17)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 17)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 17)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 02/08/17/21)
o - 00 ~ 29
(Except o - 02/08/17/21)
30
Terminals
Specification
Power
L2, N6
ON/OFF
supply
on TB3
220-240V ~ 50/60Hz
Signal
O1
Max. 1A
line
on TB3
ON/OFF
O2, N2
220-240V ~ 50/60Hz
on TB2
Max. 1A
O3
Free voltage
on TB2
O4
Free voltage
on TB3
ON/OFF
HL, HN
220-240V ~ 50/60Hz
on TB1
Max. 15A
Power
L2, N6
ON/OFF
supply
on TB3
220-240V ~ 50/60Hz
Signal
O6
Max. 1A
line
on TB3
ON/OFF
O7, N4
220-240V ~ 50/60Hz
on TB2
Max. 1A
ON/OFF
O8, N4
220-240V ~ 50/60Hz
on TB2
Max. 1A
ON/OFF
O9, N1
220-240V ~ 50/60Hz
on TB2
Max. 1A
Power
L1, N5
ON/OFF
supply
on TB3
220-240V ~ 50/60Hz
Signal
O10
Max. 1A
line
on TB3
ON/OFF
O11, N1
220-240V ~ 50/60Hz
on TB2
Max. 1A
ON/OFF
O12, N2
220-240V ~ 50/60Hz
on TB2
Max. 1A
ON/OFF
O13, N3
220-240V ~ 50/60Hz
on TB2
Max. 1A
ON/OFF
O14, N3
220-240V ~ 50/60Hz
on TB2
Max. 1A
ON/OFF
O15, N4
220-240V ~ 50/60Hz
on TB2
Max. 1A

Publicidad