POWER SUPPLY
IMPORTANT—(Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Codes or
prevailing local codes and ordinances.
Electrical Supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
requirements, call a licensed electrician before
proceeding.
location as possible in the ceiling or wall. See
page 14 for details.
accordance with local codes.
Grounding Instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of equipment-grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service
representative if you are in doubt whether the
appliance is properly grounded.
10
Installation Preparation
This Hood MUST Use an 8" Round Duct.
It Can Transition to a 3-1/4" x 12" Duct.
DO NOT use flexible plastic ducting.
NOTE: Any home ventilation system, such as a
ventilation hood, may interrupt the proper flow of
combustion air and exhaust required by fireplaces,
gas furnaces, gas water heaters and other naturally
vented systems. To minimize the chance of
interruption of such naturally vented systems, follow
the heating equipment manufacturer's guidelines
and safety standards such as those published by
NFPA and ASHRAE. When applicable, install any
makeup (replacement) air system in accordance
with local building code requirements. Visit
GEAppliances.com for available makeup air
solutions.
49-7000197 Rev. 0