www.electrolux.com
6
4. CONTROLS
L
Button
L
T1
T2
T3
T4
S1
All manuals and user guides at all-guides.com
T1
Function
Turns the lights on/off at maximum strength.
Press and hold the button for approximately 2 seconds to turn the Courtesy
Lights On/Off.
Turns the motor on/off at speed one.
Turns the Motor on at speed two.
Press and hold the button for approximately 5 seconds, with all the loads
turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm on.
The relevant LED flashes twice to confirm.
To turn the alarm off, press the button again and hold for at least 5 seconds.
The relevant LED flashes once.
Turns the Motor on at speed three.
Press and hold the button for approximately 3 seconds, with all the loads turned
off (Motor and Lights), to perform a reset. The LED S1 flashes three times.
Turns the Motor on at INTENSIVE Speed.
This speed is timed to run for 6 minutes. At the end of this time, the system
returns automatically to the speed that was set before. If it is activated with the
motor turned off, the hood will switch to OFF at the end of the time.
Press and hold for 5 seconds to enable the remote control, indicated by the
LED flashing twice.
Press and hold for 5 seconds to disable the remote control, indicated by the
LED flashing just once.
Signals the Metal Grease Filter saturation alarm, indicating that it is necessary
to wash the filters. The alarm is triggered after the Hood has been in operation
for 100 working hours.
When this is activated, it signals the Activated Charcoal Filter saturation alarm,
indicating that the filter must be changed; the Metal Grease Filters must also
be washed. The Activated Charcoal Filter saturation alarm comes into operation
after the Hood has been working for 200 hours.
T2
T3
S1
T4
Led
-
-
-
-
Flashing.
-
Flashing.
-
Flashing.
Fixed.
Flashing.