UNLOADING THE TOOL
WARNING:
engaged whenever any adjustments are made or when tool is not in use.
1. Press pusher latch release button (12).
2. Manually slide nails towards the bottom of the magazine (9).
3. Open the jam clear door (7) on the nosepiece to verify there are no nails remaining.
ADJUSTING DEPTH (FIG. E)
The depth that the fastener is driven can be adjusted using the depth adjustment
wheel (3) on the side of the tool.
WARNING:
serious injury from accidental actuation
when attempting to adjust depth,
ALWAYS:
• Remove battery pack.
• Engage trigger lock-off.
• Avoid contact with trigger during
adjustments.
Depth settings are on a sliding scale. The
left side indicating the deepest and the
right side indicating the shallowest.
1. To drive a nail deeper, rotate the depth adjustment wheel (3) downwards. This will
slide the depth adjustment indicator (4) to the left on the scale.
2. To drive a nail shallower, rotate the depth adjustment wheel (3) upwards. This will
slide the depth adjustment indicator (4) to the right on the scale.
WORK LIGHTS (FIG. F)
There are work lights (5) located on each side of the nailer.
Work lights turn on upon depressing the contact trip.
NOTE:
These work lights are for illuminating the
immediate work surface and are not intended to be
used as flashlights.
LOW BATTERY INDICATOR: The work lights will flash
and then turn off completely to indicate low battery.
JAMMED NAIL INDICATOR: The work lights will flash continually if a nail becomes
jammed in the nose piece (see Clearing a jammed nail).
STALL RELEASE (FIG. G)
WARNING:
reset it. To do so, follow instructions on clearing a stalled condition. Next remove
battery pack and then reinsert battery pack. The tool will now be operational.
If the nailer is used in a rigorous application where all available energy in the motor is
used to drive a fastener, the tool may stall. The driver blade did not complete the drive
cycle and the jam/stall indicator will flash. Rotate the stall release lever (6) on the tool and
the mechanism will release as shown in figure G.
NOTE:
The tool will disable itself and not reset
until the battery pack has been removed and
reinserted. If the unit continues to stall please
review the material and fastener length to be sure
that it is not too rigorous an application. If the driver
blade does not automatically return to the home
position after rotating the stall release lever, proceed
to "clearing a jammed nail".
The battery should always be removed and the trigger lock-off
To reduce risk of
If a stall occurs, the tool will disable itself and will require you to