Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an "Instruction Manual" which should be read
carefully as it provides important information about safety, installation, ope-
ration and maintenance.
This product complies with the applicable technical standards and regulations
regarding safety. We confirm that it complies with the following European
directives: 73/23/CEE - 93/68/CEE, 89/336/CEE - 91/236/CEE - 92/31/CEE
- 93/68/CEE, 98/37/CEE. Where applicable, it also complies with technical
standards EN60335-1, EN12453, EN12445.
IMPORTANT
For the operations of wiring and installation, refer to the regulations in effect
and, in any case, to the principles of proper workmanship.
IMPORTANT
Any operation on the parts relative to automation must be carried out by
qualified personnel (the installer).
1) AUTODIAGNOSTICS
The control unit runs a check on the operating relays and safety mecha-
nisms (photocells, sensor ridge, etc.) before performing opening and closing
cycles.
2) CONNECTION OF PHOTOCELLS AND SENSOR RIDGE:
By convention, refer to a receiver (Rx- fig.6) with 5 terminals of which terminals
1 and 2 are for the 24V AC power supply, terminal 3 is shared, terminal 4
is the normally closed contact when at rest, terminal 5 is the normally open
contact when at rest. The contact is not powered.
3) LEGEND
RX: receiver photocells or infrared ridges.
TX: transmitter photocells or infrared ridges.
The transmitters should be connected to terminals 20-44 of RIGEL 5.
The receivers should be connected to terminals 20-21 of RIGEL 5.
-
Fig.8 shows connection of RIGEL 5 with no safety device.
-
Fig. 9 shows the connection of the RIGEL 5 with 1 tested photocell.
-
Fig. 10 shows connection of RIGEL 5 with 1 safety device with verified
opening.
-
Fig.11 shows connection of RIGEL 5 with 1 safety device with verified
closing.
-
Fig. 12 shows the connection of the RIGEL 5 with 2 tested photocells
-
Fig.13 shows connection of RIGEL 5 with 2 safety devices with verified
opening.
-
Fig.14 shows connection of RIGEL 5 with 2 safety devices with verified
closure.
-
Fig.15 shows the connection of the RIGEL 5 with 3 tested photocells
-
Fig.16 shows the connection of the RIGEL 5 with 3 tested safety devices
on opening.
-
Fig.17 shows the connection of the RIGEL 5 with 3 tested safety devices
on closing.
-
Fig.18 shows the connection of the RIGEL 5 with 2 devices: 1 photocell
and 1 tested safety device on opening
-
Fig.19 shows the connection of the RIGEL 5 with 3 devices: 1 photocell, 1
safety device on opening and 1 safety device on closing, all being tested.
-
Fig.20 shows the connection of the RIGEL 5 with 4 devices: 2 photocells, 1
safety device on opening and 1 safety device on closing, all being tested.
-
Fig.21 shows the connection of the RIGEL 5 with 5 devices: 3 photocells, 1
safety device on opening and 1 safety device on closing, all being tested.
4) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
•
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
•
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
•
Keep the instructions together with the technical brochure for future
reference.
•
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
•
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
•
Do not install the product in explosive atmosphere.
•
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
INSTALLATION MANUAL
•
The Company declines all responsibility for any consequences resulting
from failure to observe GoodTechnical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
•
The installation must comply with the provisions set out by the following
European Directives:89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
•
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
•
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
•
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
•
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
•
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
•
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
•
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
•
Only use original parts for any maintenance or repair operation.
•
Do not modify the automation components, unless explicitly authorised
by the company.
•
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
•
Do not allow persons or children to remain in the automation operation
area.
•
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
•
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
•
Anything which is not expressly provided for in the present instructions,
is not allowed.
•
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
5) GENERAL OUTLINE
The RIGEL 5 control unit is supplied by the manufacturer with standard
setting.Any modifications must be entered using the UNIPRO programmer
or the incorporated display. This Control unit supports the entire EELINK
protocol.
These are its main features:
-
Control of one or two motors up to 600W power.
-
Electronic torque setting.
-
Adjustable electrodynamic braking.
-
End-of-run speed slow-down.
-
Separate opening / closing limit-switch inputs for each motor.
-
Output for zone light.
-
Separate inputs for safety devices.
-
12V output for click or suction-type electric lock.
-
Output for timer piloting.
-
Clock input.
-
Connector for traffic-light board / motor preheating.
-
Incorporated radio receiver.
The board is provided with a removable terminal board for easier maintenance
and replacement. This is supplied with a series of prewired jumpers to make
work easy for the installer.
The jumpers relate to the following terminals: 33-34, 35-36, 36-37, 38-39,
39-40, 41-42, 42-43, 52-55. If the above terminals are used, remove the
respective jumpers.
6) TECHNICAL SPECIFICATIONS
Power supply: .................................................................. 230V±10% 50Hz*
Mains/low voltage insulation: .......................................... > 2MOhm 500Vdc
Dielectric strength:..................................... mains/bty 3750Vac for 1 minute
Motor output current: .......................................................... 3.5A+3.5A max
Motor relay commutation current: .......................................................... 10A
Maximum motor power: .........................................................600W + 600W
Zone/courtesy light: ................................................................... max 150W
Supply to accessories:..................................... 24Vac (1A max absorption)
Electric lock:................................................... 12Vdc (0.5A max, 2A for 3 s)
Light/alarm output with free n.o. contact:............................ max 3A 250Vac
Gate-open warning light: ..................................................... 24Vac 3W max
Blinker:................................................................................ 230V 40W max
Dimensions: ..............................................................................see figure 1
Fuses:....................................................................................... see figure 2
(* other voltages available on request)
ENGLISH
13