MEASURING CURRENT DC
1. The red test probe to "V mA". The black test probe to "COM" (for
measurements between 200 mA and 10 A connect the red test probe to
the "10 A" connector pressing fully down).
2. Set the RANGE switch in the DC current range needed.
3. Open the circuit to be measured and connect the test probes IN
SERIES with the load to be measured.
4. Read the updated value in the digital screen.
5. Additionally, a "10 A" function was designed for intermittent use only.
The maximum time of contact with the test probes in the circuit is 10
seconds with a minimum time interval od 15 minutes between tests.
MEASURING RESISTANCE
1. The red test probe to "V mA". The black test probe to "COM".
2. Set the RANGE switch into the desired Wrange.
3. If the resistance you are measuring is connected to a circuit, turn off
the power supply and discharge all the capacitors before carrying out
the measurement.
4. Connect the test probes to the circuit to be measured.
5. Read the resistance value in the digital screen.
MEASURING DIODE
1. The red test probe in "V mA", the black test probe in "COM"
2. Set the RANGE switch in the (
) range.
3. Connect the red test probe to the diode anode to be measured and the
black test probe to the cathode.
4. A drop in mV voltage will be displayed if the diode is reversed. It
displays number "1".