Troubleshooting
You may either wire direct into the junction box for a permanent connection or wire
a molded plug into the junction box for a plug-in connection.
• Permanent connection: Connect the free end of the connection cable to a
220 – 240-Vw mains.
• Plug-in connection: Connect the free end of the connection cable to a cable with
connector and plug the connector into a 220 – 240-Vw socket.
Installing air distribution box
➤ Place the air distribution box inner wall against the inside of the ceiling template
wall (fig. e).
➤ Slide the air distribution box backwards until it touches the template (fig. f).
➤ Raise the air distribution box to the ceiling while wiggling side to side (fig. g).
➤ Hold air box in place and install the first two screws (fig. h 1). Install 6 remaining
coarse thread metric 3.5 mm x 19 mm screws in the air box mounting parts
(fig. h 2).
➤ Install the two knobs on the ends of the thermostat and selector switch shafts
(fig. h 3).
9
Troubleshooting
If your unit fails to operate or operates improperly, check the following before calling
your service center.
If the caravan is connected to the generator, check if the generator is running and
producing power.
If the caravan is connected to the power supply by a land wire, check if the wire is
sized properly to run the air conditioner load and is plugged into power supply.
Check your fuse or circuit breaker to see if it is open.
14
B3200