Submenu containing different options:
Exit from the submenu (go back to
main menu)
Programs LOCK
Protection of programs P3 to P10 for
all procediment against unintentional change of:
welding currents, slopes, timing
Trigger selection 2T/4T
Current reference EXT/Internal
Pulsations
It is still possible to select different programs and
welding procediment.
Programs P1 and P2 are unlocked, permitting
full control of relative parameters.
When pressing locked key pads or rotating the
encoder for locked parameters, the display will
flash "PG.L." to remember the active protection.
0 = unlocked (default setting)
1 = locked
Panel LOCK
Complete lock of box. All keypads
and Encoder are disabled.
When pressing locked key pads or rotating the
encoder, the display will flash "PA.L." to
remember the active protection.
0 = unlocked (default setting)
1 = locked
4-times option for torch trigger
Permit to define 6 different ways to
control the torch trigger when the machine is set
as 4Times stroke (Lift or HF). Mode 3 is called
4T-REPEAT and permits to keep the arc active
also at the end of slope down for an easier restart
of sequence. In Mode 3 the function "Second
current level" is disabled. For detailed description
of different behaviours see the following
diagrams. Select a value in the range 0...5
(1=default setting).
0 = disabled
1 = enabled (default setting)
Torch Remote Control
Makes it possible to control how the
control unit on the handle is used when torch
adjustment is enabled.
0 = Setting the current reference (factory
default).
1 = Enabling/disabling TIG-A-Tack (the TIG-A-
Tack button is disabled). The control unit is
handled as follows:
Steps 1-3:
Steps 4-7:
Steps 8-10: TIG-A-Tack is disabled
2 = Up/Down module
Enabling/Disabling
TIG-A-Tack
* Keep pressed for
constant increase/reduction
All above settings are not modified via Reset.
19
Dynamic Oxide Control
(for AC welding).
TIG-A-Tack is enabled
The trigger is disabled
Trigger
Trigger