Preliminary Test; Treating The Skin - Beurer IPL 7500 Manual De Instrucciones

Reducción permanente del vello
Ocultar thumbs Ver también para IPL 7500:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

• Remember: The device comes with a built-in skin-tone
sensor, enabling the application only on a suitable skin
range. This unique safety feature will not let you treat
areas where your skin is too dark or too tanned, even if
your general skin type is lighter.
• The device is suitable for men. However male body hair,
especially those on the chest will require more hair re-
duction sessions.

Preliminary Test

A preliminary test will determine your skin's reaction to the
device treatment and help you set the optimal energy level
for each treatment area. Perform a preliminary test on each
area you intend to treat 48 hours prior to the full treatment.
CAUTION
• Do not treat full areas with energy levels that you have
not tested before! Do not treat the tested area for at
least 48 hours after the preliminary test is completed.
1. Select an area of skin to test and place the treatment
window in full contact with the skin. Press the On/Off/
power selection button once to select Energy Level 1 and
then press the Trigger button once to emit a single pulse.
2. If you feel comfortable with the energy level, press the
On/Off/power selection button again to increase to
Energy Level 2, move the treatment window of the de-
vice to another test area of skin and press the trigger
button again.
3. If you still feel comfortable, increase the Energy Level
to 3.
4. Stop the test if you do not feel comfortable, as increas-
ing the energy level increases the risk of adverse effects.
5. If you see adverse effects such as severe redness or blis-
tering, stop the test immediately.
6. Wait 48 hours and examine the tested area. If the skin in
the test area seems normal (no response or mild redness
observed), you can proceed with a full treatment in the
highest comfortable energy level. If you see excess red-
ness, swelling, or blistering even in the low-energy level
settings, do not treat that area.

Treating the Skin

IMPORTANT:
Conduct a preliminary test before performing a full treat-
ment. See the "Preliminary Test" section above.
1. Plug the power cord into the device; the green power
LED will flash indicating the device is in standby mode.
Press the On/Off/power selection button to turn on the