Descargar Imprimir esta página

Urmet sinthesi S2 1083/74 Manual Del Usuario página 25

Poste externe audio

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DOOR OPENING TIME The position of the rotary switch (DOOR TIME) determines the activation time of the
door lock.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 8 = 80 s
Pos. 9 = 90 s
GUARANTEED CONVERSATION TIME The position of the rotary switch (CONV TIME) determines a
guaranteed conversation time, i.e. extends the busy time from the answer onwards.
The busy time is equal to the reply time (max. 60s) added to the guaranteed conversation time.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 9 = NOT ALLOWED
The guaranteed conversation time must be programmed in the same way for all system call
stations.
ADVANCED CONFIGURATION
To go to advanced confi guration, put both the rotary switches on position 9.
The door unit emits an acoustic signal and turns the signalling yellow led on.
At the end of operations, put again the door unit in stand-by mode, changing the position of one of the rotary
switches at least.
BUTTON CODES
Up to 62 buttons (in addition to the basic buttons) may be connected to the door unit using up to 4 button
expansion modules Ref. 1083/17.
By default the buttons are associate to the users from 0 to 63 of the column to which it belongs if the door
unit is confi gured as secondary unit.
DS1083-056B
All manuals and user guides at all-guidesbox.com
Pos. 2 = 20 s
Pos. 6 = 60 s
Pos. 2 = 20 s
Pos. 6 = 60 s
Pos. 3 = 30 s
Pos. 7 = 70 s
Pos. 3 = 30 s
Pos. 7 and 8 = 70 s
25

Publicidad

loading