Operation instructions:
1.short press menu key to cycle through the interface and parameters;
2. long press the menu button for 3S to enter the settings manually, this number will be
flashing, into the corresponding set project on turn, turn key adjustment parameters you want
value, after the completion of the system of automatic memory setting value and exit setup
menu;
Function declaration:
1. discharge recovery voltage: refers to the battery discharge.protection, the battery voltage to
restore voltage, open the output;
2.the discharge cut-off voltage: refers to the battery discharge to thevoltage when the load off,
to protect the battery, to prevent the battery over discharge damage.
3.load operation mode:
【24H】Load output 24Hours (except for battery under voltage)
【1-15H】Load on after sunset and closed after setting hours
【он】 Dusk to dawn
Note:
1, the light control function is controlled by the solar panel, the use of light control
function must access the solar panel, otherwise the light had no effect.
2. Load symbol 【】 Light, only that the load output has been turned on, and there is no
connection to the load.
As long as it is not set to 【1-15H】 Or 【OH】 model.(The optical delay model),Battery not
under pressure condition(Battery symbol does not blink),Single short press the turn key can
open /Close load output.
6. TROUBLE SHOOTING
Situation
Charge icon not on when
sunny
Load icon off
Load icon slow flashing
Power off
Probable cause
Solar panel opened or reversed
Mode setting wrong
Battery low
Over load
Short circuit prolection
Battery too low/ reverse
4
Solution
Reconnect
Set again
Recharge
Reduce load watt
Remove short circuit, 1 minutes
or so automatic recovery
Check battery/connection