English
ADJUSTING THE NAILING DEPTH
To assure that each nail penetrates to the same depth,
be sure that the Nailer is always held fi rmly against the
workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
1 Remove the battery from the Nailer.
2 If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half-turn increments.
2
Too Deep
2
Too Shallow
If nails are driven too shallow, turn the adjuster to the
deep side.
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the battery to the Nailer.
ALWAYS WEAR SAFETY GLASSES.
Perform a nailing test.
5 Remove the battery from the Nailer.
6 Choose a suitable position for adjuster.
26
Battery
Turn Adjuster
Flush
Turn Adjuster
Flush
USING THE HOOK
● When using the hook, turn off the power
switch (green light "OFF"). Pay suffi cient
attention so that the main equipment does
not fall.
If the tool falls, there is a risk of accident.
Hook can be installed on the left or right side. (excluding
NT1865DMA(S))
(1) Securely hold the main unit and remove the screw
using an allen wrench.
(2) Remove the hook and hook plate.
(3) Install the hook on the other side and securely
fasten with screw.
NOTE
Hook can be used as a hanger.
WARNING