English
PROBLEM
Nailer doesn't operate
(Power switch ON).
Nailer operates, but no nail is driven.
Weak drive.
Slow to cycle.
Drives too deep.
Skipping nails.
Intermittent feed.
Nails jam.
Driven nail is bent.
30
CHECK METHOD
Nailer not enough pressed against
workpiece.
Trigger not enough pulled.
More than 2 seconds pass from push
lever ON to trigger ON (or trigger ON
to push lever ON).
Preventive mechanism activated.
(No nails, or too few fasteners
remaining) (NT1865DMA(S) /
NT1865DM(S) only)
Lock lever(Trigger lock function) is
"ON" position.
Machine is too cold (below 23°F
(-5°C)) or too hot. (LED light blinks at
regular intervals, and power switch
goes off after 10 seconds.) (Refer to
page 19)
Damaged internal electronics.
Magazine is dirty.
Check for a jam.
Driver blade worn or damaged?
Ribbon spring weakened or
damaged?
Nail feeder damaged?
Check for proper nails.
Check position of nailing depth
adjustment adjuster.
Driver blade worn?
Compressed air pressure has
become low.
Damaged internal electronics.
Check position of nailing depth
adjustment adjuster.
Check for proper nails.
Nail feeder damaged?
Ribbon spring weakened or
damaged?
Driver blade worn or damaged?
Check for proper nails.
Driver blade worn or damaged?
CORRECTION
Hold nailer fi rmly and press to the
workpiece completely.
Pull the trigger fi rmly.
Make sure that less than 2 seconds
pass between push lever ON and
trigger ON (or between trigger ON
and push lever ON).
Reload the nails into magazine.
Set Lock lever to "OFF" position.
(Refer to page 19 – 20)
Allow the nailer to cool or warm-up
throughly in adequate condition.
Contact metabo HPT for inspection.
Blow and wipe clean the magazine.
Clear a jam (refer to page 27).
Contact metabo HPT for inspection.
Replace ribbon spring.
Replace nail feeder.
Use only recommended nails.
Readjust according to page 26.
Contact metabo HPT for inspection.
Contact metabo HPT for inspection.
Contact metabo HPT for inspection.
Readjust according to page 26.
Use only recommended nails.
Replace nail feeder.
Replace ribbon spring.
Contact metabo HPT for inspection.
Use only recommended nails.
Contact metabo HPT for inspection.